Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 65
Filter
1.
Int. j. cardiovasc. sci. (Impr.) ; 36: e20200312, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1430488

ABSTRACT

Abstract Background Dental anesthetic management in implantable cardioverter defibrillator (ICD) recipients with cardiac channelopathies (CCh) can be challenging due to the potential risk of life-threatening arrhythmias and appropriate ICD therapies during procedural time. Objectives The present study assessed the hypothesis that the use of local dental anesthesia with 2% lidocaine with 1:100,000 epinephrine or without a vasoconstrictor can be safe in selected ICD and CCh patients, not resulting in life-threatening events (LTE). Methods Restorative dental treatment under local dental anesthesia was made in two sessions, with a wash-out period of 7 days (cross-over trial), conducting with a 28h - Holter monitoring, and 12-lead electrocardiography, digital sphygmomanometry, and anxiety scale assessments in 3 time periods. Statistical analysis carried out the paired Student's t test and the Wilcoxon signed-rank test. In all cases, a significance level of 5% was adopted. All patients were in stable condition with no recent events before dental care. Results Twenty-four consecutive procedures were performed in 12 patients (9 women, 3 men) with CCh and ICD: 7 (58.3%) had long QT syndrome (LQTS), 4 (33.3%) Brugada syndrome (BrS), and 1 (8.3%) Catecholaminergic polymorphic ventricular tachycardia (CPVT). Holter analysis showed no increased heart rate (HR) or sustained arrhythmias. Blood pressure (BP), electrocardiographic changes and anxiety measurement showed no statistically significant differences. No LTE occurred during dental treatment, regardless of the type of anesthesia. Conclusion Lidocaine administration, with or without epinephrine, can be safely used in selected CCh-ICD patients without LTE. These preliminary findings need to be confirmed in a larger population with ICD and CCh.

2.
Arq. bras. cardiol ; 120(2): e20210941, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420185

ABSTRACT

Resumo Há uma enorme disparidade entre os países de alta renda e outros em termos de acesso a dispositivos médicos cardíacos, como marca-passos e desfibriladores implantáveis. Os custos são uma das principais barreiras ao uso de dispositivos cardíacos nesses países. Existem iniciativas internacionais que visam reduzir essa disparidade, e o reuso de marca-passos tem sido discutido como uma possível alternativa. O conceito de reutilização de marca-passos não é novo; entretanto, estudos recentes têm se mostrado seguros, éticos e eficazes para aqueles que precisam de dispositivos eletrônicos cardíacos implantáveis e não tem como adquiri-los. Parte dos países de língua portuguesa, especialmente na África, precisam de uma resposta imediata que beneficie seus inúmeros pacientes que sofrem de arritmias tratáveis.


Abstract There is a gap between high-income countries and others in terms of access to medical cardiac devices, such as pacemakers and implantable cardioverter defibrillators. Costs are one of the main barriers to the use of cardiac devices in these countries. There are international initiatives that aim to reduce the gap. The reuse of pacemakers has been discussed as a possible alternative to this problem. The concept of reusing pacemakers is not new; however, recent studies have proven to be safe, ethical, and effective for those who need cardiac implantable electronic devices and cannot afford them. Part of the Portuguese-speaking countries, especially in Africa, need an immediate response that benefits their countless patients who suffer from treatable arrhythmias.

3.
Arq. bras. cardiol ; 120(8): e20220833, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1505742

ABSTRACT

Resumo Fundamento: A morte súbita cardíaca (MSC), decorrente de arritmias ventriculares, é a principal complicação da cardiomiopatia hipertrófica (CMH). A microalternância da onda T (MAOT) está associada à ocorrência de arritmias ventriculares em diversas cardiopatias, mas seu papel na CMH permanece incerto. Objetivo: Avaliar associação da MAOT com a ocorrência de MSC ou arritmias ventriculares malignas em pacientes com CMH. Método: Pacientes com diagnóstico de CMH e classe funcional I-II (NYHA) foram selecionados de forma consecutiva. No início do seguimento os participantes realizaram a avaliação da MAOT pela metodologia da média móvel modificada no teste de esforço. Os resultados foram classificados em alterado ou normal. O desfecho foi composto por MSC, fibrilação ventricular, taquicardia ventricular sustentada (TVS) e terapia apropriada do cardioversor desfibrilador implantável (CDI). O nível de significância estatística foi de 5%. Resultados: Um total de 132 pacientes (idade média de 39,5±12,6 anos) foram incluídos, com tempo de seguimento médio de 9,5 anos. A MAOT foi alterada em 74 (56%) participantes e normal em 58 (44%). Durante o seguimento, nove (6,8%) desfechos ocorreram, com prevalência de 1,0%/ano, sendo seis casos de MSC, dois choques apropriados do CDI e um episódio de TVS. MAOT alterada foi associada à taquicardia ventricular não sustentada no Holter (p=0,016), espessura septal≥30 mm (p<0,001) e resposta inadequada da pressão arterial ao esforço (p=0,046). Cinco pacientes (7%) e quatro pacientes (7%) com MAOT alterada e normal, respectivamente, apresentaram desfecho primário [OR=0,85(IC95%: 0,21-3,35, p=0,83)]. Curvas de eventos de Kaplan-Meir não apresentaram diferenças entre MAOT normal e alterada. Conclusão: A MAOT alterada não foi associada à ocorrência de MSC ou arritmias ventriculares potencialmente fatais em pacientes com CMH, e a baixa taxa desses eventos em um seguimento em longo prazo sugere o bom prognóstico dessa cardiopatia.


Abstract Background: Sudden cardiac death (SCD) resulting from ventricular arrhythmia is the main complication of hypertrophic cardiomyopathy (HCM). Microvolt T-wave alternans (MTWA) is associated with the occurrence of ventricular arrhythmias in several heart diseases, but its role in HCM remains uncertain. Objective: To evaluate the association of MTWA with the occurrence of SCD or potentially fatal ventricular arrhythmias in HCM patients in a long-term follow-up. Methods: Patients diagnosed with HCM and NYHA functional class I-II were consecutively selected. At the beginning of the follow-up, the participants performed the MTWA evaluation using the modified moving average during the stress test. The results were classified as altered or normal. The composite endpoint of SCD, ventricular fibrillation, sustained ventricular tachycardia (SVT) or appropriate implantable cardiac defibrillation (ICD) therapy was assessed. The level of significance was set at 5%. Results: A total of 132 patients (mean age of 39.5 ± 12.6 years) were recruited and followed for a mean of 9.5 years. The MTWA test was altered in 74 (56%) participants and normal in 58 (44%). Nine events (6.8%) occurred during the follow-up, with a prevalence of 1.0%/year - six SCDs, two appropriate ICD shocks and one episode of (SVT). Altered MTWA was associated with non-sustained ventricular tachycardia on Holter (p = 0.016), septal thickness ≥30 mm (p < 0.001) and inadequate blood pressure response to effort (p = 0.046). Five patients with altered MTWA (7%) and four patients with normal MTWA (7%) had the primary outcome [OR = 0.85 (95% CI: 0.21 - 3.35, p=0.83)]. Kaplan-Meir event curves showed no differences between normal and altered MTWA. Conclusion: Altered MTWA was not associated with the occurrence of SCD or potentially fatal ventricular arrhythmias in HCM patients, and the low rate of these events during long-term follow-up suggests the good prognosis of this heart disease.

4.
Arq. bras. cardiol ; 119(6): 923-928, dez. 2022. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420126

ABSTRACT

Resumo Fundamento A morte súbita cardíaca (MSC) é a causa mais comum de óbito na cardiomiopatia crônica da doença de Chagas (CCDC). Visto que muitos pacientes com CCDC que são candidatos a receber um cardioversor desfibrilador implantável (CDI) atendem a critérios que sugerem alto risco de apresentarem limiares de desfibrilação elevados, sugere-se realizar um teste de limite de desfibrilação (LDF). Objetivos Investigamos o uso do teste de LDF em pacientes com CCDC, com enfoque nos óbitos relacionados ao implante do CDI e na ocorrência de eventos arrítmicos e o tratamento oferecido durante o seguimento de longo prazo. Métodos Avaliações retrospectivas de 133 pacientes com CCDC que receberam CDI, principalmente para prevenção secundária. Foram coletados dados demográficos, clínicos e laboratoriais, escore de Rassi e dados do teste de LDF. Adotou-se p<0,05 como estatisticamente significativo. Resultados A média de idade foi 61±13 anos, e 72% da amostra era do sexo masculino. A fração de ejeção basal do ventrículo esquerdo foi 40±15%, e o escore de Rassi médio foi 10±4 pontos. Não ocorreram óbitos durante o teste de LDF, e não foram documentadas falhas do CDI. Foi identificada relação entre escore de Rassi basal mais elevado e LDFs mais elevados (ANOVA =0,007). O tempo médio até o primeiro choque foi de 474±628 dias, mas a aplicação de choque foi necessária em apenas 28 (35%) pacientes com TV, visto que a maioria dos casos se resolveu espontaneamente ou através da programação de ATP. Após seguimento clínico de 1728±1189 dias, em média, ocorreram 43 óbitos, relacionados principalmente a insuficiência cardíaca progressiva e sepse. Conclusões Um teste de LDF de rotina pode não ser necessário para pacientes com CCDCs que receberam CDI para prevenção secundária. LDFs elevados parecem ser incomuns e podem estar relacionados a escore de Rassi elevado.


Abstract Background Sudden cardiac death is the most common cause of death in chronic Chagas cardiomyopathy (CCC). Because most CCC patients who are candidates for implantable cardioverter-defibrillators (ICD) meet criteria for high defibrillation threshold values, a defibrillator threshold test (DTT) is suggested. Objectives We investigated the use of DTT in CCC patients, focusing on deaths related to ICD and arrhythmic events, as well as treatment during long-term follow-up. Methods We retrospectively evaluated 133 CCC patients who received an ICD mainly for secondary prevention. Demographic, clinical, laboratory data, Rassi score, and DTT data were collected, with p < 0.05 considered significant. Results The mean patient age was 61 (SD, 13) years and 72% were men. The baseline left ventricular ejection fraction was 40 (SD, 15%) and the mean Rassi score was 10 (SD, 4). No deaths occurred during DTT and no ICD failures were documented. There was a relationship between higher baseline Rassi scores and higher DTT scores (ANOVA = 0.007). The mean time to first shock was 474 (SD, 628) days, although shock was only necessary for 28 (35%) patients with ventricular tachycardia, since most cases resolved spontaneously or through antitachycardia pacing. After a mean clinical follow-up of 1728 (SD, 1189) days, 43 deaths occurred, mainly related to progressive heart failure and sepsis. Conclusions A routine DTT may not be necessary for CCC patients who receive an ICD for secondary prevention. High DTT values seem to be unusual and may be related to high Rassi scores.

5.
Nursing ; 25(294): 8954-8969, nov.2022.
Article in English, Portuguese | LILACS, BDENF | ID: biblio-1402600

ABSTRACT

Objetivo:Identificar o perfil dos pacientes submetidos à inserção de dispositivos cardíacos eletrônicos implantáveis em um hospital de referência do Rio Grande do Norte.Método:Trata-se de um estudo descritivo, exploratório, retrospectivo dos últimos 03 anoscom abordagem quantitativa. Amostragem foiselecionada por conveniência. A coleta de dados ocorreu entre outubrode 2017 a março de 2018.Resultados: A amostra foi composta por 215prontuários,destes 182 foram analisados.Implantarammarca-passos63,7% e 28% cardiodesfibriladores, corresponderam ao sexo masculino69,3%,com média de idade 65 e 49.Entre as comorbidades,a Hipertensão Arterial Sistêmicaabrangeu 87,4%.Evidenciaram-se os bloqueios atrioventriculares como principal causa para implantes (35%), seguidos das miocardiopatias (12%).Conclusão:Percebeu-se que, os indivíduos que implantaram marcapassos eram acometidos por bradiarritmias,enquanto cardiodesfibriladores por taquiarritmias. As complicações pós-operatórias e intercorrências durante o procedimento foram de baixo risco. Salienta-se, que no manejo desses usuários é fundamental a elaboração de um protocolo, visando aperfeiçoar o cuidado.(AU)


Objective: Toidentifytheprofileofpatientsundergoinginsertionof implantable electroniccardiacdevices in a reference hospital in Rio Grande do Norte. Method: Thisis a descriptive, exploratory,retrospective studyofthelastthreeyearswith a quantitativeapproach. Samplingwasselectedby convenience. Data collectionoccurredbetweenOctober 2017 to March 2018. Results: Samplecomposedof 215 medical records, ofthese 182 wereanalyzed. Implantedpacemakers 63.7% and 28% cardiodesfibrillators, corresponded tothe male gender 69.3%, withaverageage 65 and 49. Amongthecomorbidities, Systemic Arterial Hypertensioncovered 87.4%. Theatrioventricular blocks wereevidenced as themain cause forimplantation (35%), followedbymyocardiopathies (12%). Conclusion: Itwasnoticedthatindividualswhoimplantedpacemakerswereaffectedbybradyarrhythmias, whilecardioverter-defibrillatorswereaffe ctedbytachyarrhythmias. Thepostoperativecomplications and complicationsduringtheprocedurewerelowrisk. Itisemphasizedthat in themanagementoftheseusersitisessentialtodevelop a protocol, aimingtoimprove care.(AU)


Objetivo: identificar el perfil de los pacientes sometidos a la inserción de dispositivos cardíacos electrónicos implantables en el hospital de referencia de Rio Grande do Norte. Método: se trata de un estudio descriptivo, exploratorio, retrospectivo de los últimos 3 años con enfoque cuantitativo. El muestreo fue seleccionado por conveniencia. La recolección de datos se llevó a cabo entre octubre de 2017 y marzo de 2018. Resultados: muestra compuesta por 215 historias clínicas, de las cuales se analizaron 182. Marcapasos implantados 63,7% y desfibriladores cardioversores 28%, correspondieron al sexo masculino 69,3%, con una edad media de 65 y 49 años. Entre las comorbilidades, la Hipertensión Arterial Sistémica cubrió el 87,4%. Los bloqueos auriculoventriculares se evidenciaron como la principal causa de implantes (35%), seguida de las miocardiopatías (12%). Conclusión: se notó que, los portadores de marcapasos se vieron afectados por bradiarritmias, mientras que los desfibriladores cardioversores por taquiarritmias. Las complicaciones postoperatorias y las complicaciones durante el procedimiento fueron de bajo riesgo. Cabe señalar que en el manejo de estos usuarios es fundamental la elaboración de un protocolo, con el fin de mejorar la atención.(AU)


Subject(s)
Pacemaker, Artificial , Arrhythmias, Cardiac , Surgical Procedures, Operative , Cardiology , Defibrillators, Implantable
6.
Int. j. cardiovasc. sci. (Impr.) ; 34(6): 692-701, Nov.-Dec. 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421759

ABSTRACT

Abstract Background: Implantable cardiac defibrillators (ICDs) therapy for primary prevention (PP) of sudden cardiac arrest (SCA) is well-established but underutilized globally. The Improve SCA study has identified a cohort of patients called 1.5 primary prevention (1.5PP), based on PP patients with the presence of documented risk factors: non-sustained ventricular tachycardia, frequent premature ventricular contractions, left ventricular ejection fraction < 25%, and pre-syncope or syncope. Objective: This study evaluated the cost-effectiveness of ICD therapy compared to no ICD among 1.5PP patients in the Brazilian public healthcare system. Methods: Modified inputs to a published Markov model were applied to compare costs and outcomes of ICD therapy to no ICD therapy from the Brazilian payer's perspective. Mortality and utility estimates were obtained from the IMPROVE SCA trial. Additional effectiveness inputs were sourced from the literature. Cost inputs were obtained from the Brazilian Unified Health System and the Ministry of Health. Costs were discounted at 4.7%; quality-adjusted life years (QALYs) were discounted at 1.45%. This study applied a willingness-to-pay (WTP) value of three times Brazil's gross domestic product (GDP) in 2017, R$105,723 (Brazilian Real). Results: The total discounted lifetime costs for ICD therapy were R$100,920 compared to R$43,866 for no ICD therapy. Total discounted QALYs for ICD therapy and no ICD therapy were 9.85 and 7.15, respectively. The incremental cost effectiveness ratio was R$21,156 per QALY and less than the R$105,723 WTP threshold. Results from sensitivity analyses were consistent with base case results. Conclusions: ICD therapy compared to no ICD therapy is cost-effective in the 1.5PP population in Brazil. (Int J Cardiovasc Sci. 2021; [online].ahead print, PP.0-0)

8.
Arq. bras. cardiol ; 117(3): 531-541, Sept. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1339195

ABSTRACT

Resumo Fundamento: A estratificação de risco continua sendo clinicamente desafiadora em pacientes com insuficiência cardíaca (IC) de etiologia não isquêmica. A galectina-3 é um marcador sérico de fibrose que pode ajudar no prognóstico. Objetivo: Determinar o papel da galectina-3 como preditora de eventos arrítmicos graves e mortalidade total. Métodos: Este é um estudo de coorte prospectivo que incluiu 148 pacientes com IC não isquêmica. Todos os pacientes foram submetidos a uma avaliação clínica e laboratorial abrangente para coleta de dados de referência, incluindo níveis de galectina-3 sérica. O desfecho primário foi a ocorrência de síncope arrítmica, intervenções apropriadas do cardioversor desfibrilador implantável, taquicardia ventricular sustentada ou morte súbita cardíaca. O desfecho secundário foi a morte por todas as causas. Para todos os testes estatísticos, considerou-se significativo o valor p<0,05 (bicaudal). Resultados: Em seguimento mediano de 941 dias, os desfechos primário e secundário ocorreram em 26 (17,5%) e 30 (20%) pacientes, respectivamente. A galectina-3 sérica>22,5 ng/mL (quartil mais alto) não foi preditora de eventos arrítmicos graves (HR: 1,98; p=0,152). Os preditores independentes do desfecho primário foram diâmetro diastólico final do ventrículo esquerdo (DDFVE)>73 mm (HR: 3,70; p=0,001), ventilação periódica durante o exercício (VPE) no teste de esforço cardiopulmonar (HR: 2,67; p=0,01) e taquicardia ventricular não sustentada (TVNS)>8 batimentos na monitorização por Holter (HR: 3,47; p=0,027). Os preditores de morte por todas as causas foram: galectina-3>22,5 ng/mL (HR: 3,69; p=0,001), DDFVE>73 mm (HR: 3,35; p=0,003), VPE (HR: 3,06; p=0,006) e TVNS>8 batimentos (HR: 3,95; p=0,007). A ausência de todos os preditores de risco foi associada a um valor preditivo negativo de 91,1% para o desfecho primário e 96,6% para a mortalidade total. Conclusões: Em pacientes com IC não isquêmica, níveis elevados de galectina-3 não foram preditores de eventos arrítmicos graves, mas foram associados à mortalidade total. A ausência de preditores de risco revelou um subgrupo prevalente de pacientes com IC com excelente prognóstico.


Abstract Background: Risk stratification remains clinically challenging in patients with heart failure (HF) of non-ischemic etiology. Galectin-3 is a serum marker of fibrosis that might help in prognostication. Objective: To determine the role of galectin-3 as a predictor of major arrhythmic events and overall mortality. Methods: We conducted a prospective cohort study that enrolled 148 non-ischemic HF patients. All patients underwent a comprehensive baseline clinical and laboratory assessment, including levels of serum galectin-3. The primary outcome was the occurrence of arrhythmic syncope, appropriate implantable cardioverter defibrillator therapy, sustained ventricular tachycardia, or sudden cardiac death. The secondary outcome was all-cause death. For all statistical tests, a two-tailed p-value<0.05 was considered significant. Results: In a median follow-up of 941 days, the primary and secondary outcomes occurred in 26 (17.5%) and 30 (20%) patients, respectively. Serum galectin-3>22.5 ng/mL (highest quartile) did not predict serious arrhythmic events (HR: 1.98, p=0.152). Independent predictors of the primary outcome were left ventricular end-diastolic diameter (LVEDD)>73mm (HR: 3.70, p=0.001), exercise periodic breathing (EPB) on cardiopulmonary exercise testing (HR: 2.67, p=0.01), and non-sustained ventricular tachycardia (NSVT)>8 beats on Holter monitoring (HR: 3.47, p=0.027). Predictors of all-cause death were galectin-3>22.5 ng/mL (HR: 3.69, p=0.001), LVEDD>73mm (HR: 3.35, p=0.003), EPB (HR: 3.06, p=0.006), and NSVT>8 beats (HR: 3.95, p=0.007). The absence of all risk predictors was associated with a 91.1% negative predictive value for the primary outcome and 96.6% for total mortality. Conclusions: In non-ischemic HF patients, elevated galectin-3 levels did not predict major arrhythmic events but were associated with total mortality. Absence of risk predictors revealed a prevalent subgroup of HF patients with an excellent prognosis.


Subject(s)
Humans , Defibrillators, Implantable , Galectin 3/blood , Heart Failure , Prognosis , Predictive Value of Tests , Prospective Studies , Risk Factors , Death, Sudden, Cardiac
10.
Univ. salud ; 23(2): 109-119, mayo-ago. 2021. tab
Article in Spanish | LILACS, COLNAL | ID: biblio-1252314

ABSTRACT

Introducción: Las enfermedades cardiovasculares han provocado el incremento de arritmias en la población, aumentando el uso de dispositivos como el cardiodesfibrilador, que, si bien previene las arritmias, puede afectar la calidad de vida. Objetivo: Describir la asociación que existe entre la calidad de vida relacionada con la salud, la ansiedad y la depresión en personas portadoras de un cardiodesfibrilador. Materiales y métodos: Estudio cuantitativo, descriptivo correlacional, de corte transversal, donde participaron 85 pacientes con implante de cardiodesfibrilador. Se aplicó una ficha sociodemográfica, los instrumentos Cuestionario de Salud (SF-36), el Inventario de Ansiedad y Depresión de Beck. Resultados: El 81,2% de los participantes fueron hombres con rango de edad 36-92 años. La calidad de vida relacionada con la salud mostró correlación negativa media con respecto a la ansiedad (r=‒0,622; p<0,001) y moderada, respecto a la depresión (rs=‒0,599; p<0,001). Conclusiones: Portar un cardiodesfibrilador puede desencadenar ansiedad y depresión, si estos no se intervienen oportunamente la calidad de vida relacionada con la salud puede deteriorarse, por ello, es importante implementar acciones tempranas que generen bienestar.


Introduction: Cardiovascular diseases have caused a rise in arrhythmias, increasing the use caridoverter defibrillators. Although, these devices prevent arrhythmias, they may also affect the quality of life. Objective: To describe the association between quality of life and health, anxiety and depression in people who use cardioverter defibrillators. Materials and methods: A qualitative, descriptive, correlational and cross-sectional study was carried out with 85 patients using implantable cardioverter defibrillator. Sociodemographic records, the Health Questionnaire (SF-36), and the Beck Anxiety and Depression Questionnaire were used. Results: 81.2% of participants were men with their ages ranging between 36 and 92 years. The health-related quality of life showed a negative correlation with respect to anxiety (r=- 0.622) and a slight correlation with depression (rs=-0.599; p<0.001). Conclusions: The use of a cardioverter-defibrillator can trigger anxiety and depression that can deteriorate the health-related quality of life if not timely intervened. It is important to implement early actions that generate well-being.


Subject(s)
Anxiety , Quality of Life , Defibrillators, Implantable , Catheters, Indwelling , Death, Sudden , Depression , Cardiovascular Nursing
11.
Rev Rene (Online) ; 22: e61117, 2021. tab
Article in Portuguese | BDENF, LILACS | ID: biblio-1155273

ABSTRACT

RESUMO Objetivo investigar a relação entre gênero e idade com sintomas de ansiedade, depressão e ansiedade cardíaca em pacientes com cardiodesfibrilador implantável. Métodos estudo transversal, com 76 pacientes com dispositivo atendidos em um hospital universitário. Para a coleta de dados, utilizaram-se formulário sociodemográfico/clínico e duas escalas validadas no Brasil. Na análise, adotaram-se os testes qui-quadrado, exato de Fischer e Mann-Whitney, com nível de significância de 5%. Resultados observou-se que os grupos foram homogêneos entre si quanto ao gênero e à idade. As mulheres apresentaram medianas maiores, tanto nos sintomas de ansiedade quanto nos de depressão, com significância estatística. Apresentaram medianas maiores também nos sintomas de ansiedade cardíaca, porém sem significância estatística. Com relação à idade, não foram encontradas diferenças significativas para os sintomas investigados. Conclusão as mulheres apresentaram mais sintomas de ansiedade e depressão, todavia não houve relação entre a idade dos pacientes com os respectivos sintomas.


ABSTRACT Objective to investigate the relationship between gender and age with symptoms of anxiety, depression and cardiac anxiety in patients with implantable cardioverter-defibrillator. Methods cross-sectional study, with 76 patients with device attended in a university hospital. For data collection, a sociodemographic/clinical form and two validated scales were used in Brazil. In the analysis, the chi-square tests, exact Fischer and Mann-Whitney, with a significance level of 5% were adopted. Results it was observed that the groups were homogeneous in terms of gender and age. Women presented higher medians in both anxiety and depression symptoms, with statistical significance. They also presented higher medians in symptoms of cardiac anxiety, but without statistical significance. Regarding age, no significant differences were found for the symptoms investigated. Conclusion women presented more symptoms of anxiety and depression; however there was no relationship between the age of the patients and their symptoms.


Subject(s)
Anxiety , Arrhythmias, Cardiac , Perioperative Nursing , Defibrillators, Implantable , Defibrillators , Depression
13.
Rev. argent. cardiol ; 88(5): 429-433, set. 2020. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1251016

ABSTRACT

RESUMEN Introducción: La prevención de la muerte súbita y el tratamiento de la insuficiencia cardíaca son temas de gran importancia. Para prevenir la muerte súbita y mejorar el pronóstico de la insuficiencia cardíaca se utilizan los cardiodesfibriladores y cardioresincronizadores. Objetivos: Evaluar la cantidad y tipo de dispositivos implantados en nuestro país, así como las características de los pacientes, las complicaciones agudas y las que se presentan en el seguimiento. Material y métodos: Se realizó un estudio observacional, prospectivo, multicéntrico en centros de salud con la capacidad de implantar cardiodesfibriladores y cardioresincronizadores. Se incluyeron pacientes a los que se les realizó implante de estos dispositivos desde enero del 2016 hasta enero de 2017, con un seguimiento de 12 meses. Resultados: Se incluyeron 249 pacientes (edad promedio de 64,8 ± 13,7 años, 73,9% de sexo masculino, 72,1% con Fey < 35%). La etiología subyacente de la miocardiopatía era isquémica en el 39,8%, dilatada 26,7% y chagásica en el 11,2% de los casos. El 58% de los implantes realizados fueron cardiodesfibriladores y el 39%, cardiodesfibriladores asociados con cardioresincronizadores. El 84% de los procedimientos fueron primoimplantes. La indicación más frecuente del implante fue por prevención primaria de muerte súbita (67,9%). La tasa de complicaciones menores fue del 4,4% y no se reportaron complicaciones mayores. Conclusiones: El siguiente registro evidenció una gran proporción de implantes en pacientes con cardiopatía isquémica, la indicación principal fue por prevención primaria de muerte súbita y la tasa de complicaciones fue similar a la reportada internacionalmente.


ABSTRACT Background: Prevention of sudden death and treatment of heart failure are very important topics. Implantable cardioverter-defibrillator and cardiac resynchronization devices are used to prevent sudden death and improve heart failure symptoms and prognosis. Objectives: The aim of this study was to evaluate the number, type of implanted devices, clinical characteristics of the patients and acute and follow-up complications. Methods: An observational, prospective, multicenter study was carried out in healthcare centers with the capacity to implant cardioverter-defibrillator and cardiac resynchronization devices. The study included all patients who underwent implantation of these devices from January 2016 to January 2017, with a 12-month follow-up. Results: A total of 249 patients (73.9% men) with mean age of 64.8±13.7 years, and 72.1% with ejection fraction <35%, were included in the study. The underlying cardiomyopathy etiology was ischemic in 39.8% of cases, dilated in 26.7% and chagasic in 11.2%. Fifty-eight percent of implants were implantable cardioverter-defibrillators and 39% were cardioverter-defibrillators associated with cardiac resynchronization devices. In 84% of cases, procedures were first implants. The most frequent indica-tion of implantation was for primary prevention of sudden death (67.9%). Minor complication rate was 4.4% and no major complications were reported. Conclusions: The present registry evidenced a large proportion of cardioverter-defibrillator and cardiac resynchronization implants in patients with ischemic heart disease. The main indication was for primary prevention of sudden death and the complication rate was similar to that reported internationally.

14.
Arq. bras. cardiol ; 115(2): 197-204, ago., 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131297

ABSTRACT

Resumo Fundamento A estratificação de risco para morte súbita (MS) na cardiomiopatia hipertrófica (CMH) baseia-se em algoritmos distintos propostos pela diretriz norte-americana, ACCF/AHA 2011 e europeia, ESC 2014. Objetivo Analisar o modelo ESC 2014 na determinação do risco de MS e indicação de cardiodesfibrilador implantável (CDI) em prevenção primária na CMH por meio de confrontação com a normativa norte-americana. Métodos Foi avaliada uma coorte de pacientes com CMH, calculado o escore ESC HCM-Risk-SCD e analisada a concordância dos critérios de indicação de CDI entre as duas diretrizes pelo coeficiente de Kappa. O nível de significância adotado nas análises estatísticas foi de 5%. Resultados Em 90 pacientes consecutivos, seguidos por 6±3 anos, o escore calculado foi de 3,2±2,5%. Os preditores que mais contribuíram para o cálculo nas faixas de baixo (1,88% [1,42-2,67]), médio (5,17% [4,89-5,70]) e alto risco (7,82% [7,06-9,19]) foram espessura parietal máxima do ventrículo esquerdo (1,60% [1,25-2,02] ; 3,20% [3,18-3,36] ; 4,46% [4,07-5,09]), diâmetro do átrio esquerdo (0,97% [0,83-1,21]; 1,86% [1,67-2,40]; 2,48% [2,21-3,51]) e idade (-0,91% [0,8-1,13]; -1,90% [1,12-2,03]; -2,34% [1,49-2,73]). O modelo europeu reduziu as recomendações de CDI em 32 (36%) pacientes. Entre os 43 (48%) em classe IIa pela ACCF/AHA , 8 (18%) migraram para IIb e 24 (56%) para III. Baixa concordância foi identificada entre as duas sistematizações, Kappa = 0,355, p = 0,0001. Dos 8 (9%) pacientes com MS ou choque apropriado, 4 (50%) atingiram indicação IIa pela ACCF/AHA , mas nenhum pela ESC . Conclusão Baixa concordância foi identificada entre as diretrizes analisadas. O novo modelo reduziu as indicações de CDI, notadamente em classe IIa, mas deixou desprotegida a totalidade de pacientes com MS ou choque apropriado. (Arq Bras Cardiol. 2020; 115(2):197-204)


Abstract Background Risk stratification for sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) is based on different algorithms proposed by the 2011 ACCF/AHA and 2014 ESC guidelines. Objective To analyze the 2014 ESC model for SCD risk stratification and primary prevention ICD (implantable cardioverter defibrillator) in HCM in comparison to the North American guideline. Methods An HCM cohort was evaluated and the ESC HCM-Risk SCD score was calculated. Agreement of ICD recommendations criteria between the two guidelines was analyzed with Kappa coefficient. P<0.05 was adopted for the statistical analysis. Results In 90 consecutive patients followed for 6±3 years, the mean calculated ESC risk score was 3.2±2.5%. The risk predictors that have mainly contributed to the score calculation in the low (1.88% [1.42-2.67]), intermediate (5.17% [4.89-5.70]) and high-risk (7.82% [7.06-9.19]) categories were: maximal left ventricular wall thickness (1.60% [1.25-2.02]; 3.20% [3.18-3.36]; 4.46% [4.07-5.09]), left atrial diameter (0.97% [0.83-1.21]; 1.86% [1.67-2.40]; 2.48% [2.21-3.51]) and age (-0.91% [0.8-1.13]; -1.90% [1.12-2.03]; -2.34% [1.49-2.73]). The European model decreased the ICD recommendations in 32 (36%) patients. Among the 43 (48%) individuals with class IIa recommendation under the 2011 ACCF/AHA guideline, 8 (18%) were downgraded to class IIb and 24 (56%) to class III. Low agreement was found between the two systems: Kappa=0.355 and p=0.0001. In 8 (9%) patients with SCD or appropriate shock, 4 (50%) met class IIa indication with the 2011 ACCF/AHA guideline, but none achieved this class of recommendation with the 2014 ESC model. Conclusion Low agreement was found between the two strategies. The novel ESC model decreased the ICD recommendations, especially in those with class IIa recommendation, but left unprotected all patients with SCD or appropriate shock. (Arq Bras Cardiol. 2020; 115(2):197-204)


Subject(s)
Humans , Cardiomyopathy, Hypertrophic/complications , Defibrillators, Implantable , Primary Prevention , Risk Factors , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Risk Assessment
17.
Int. j. cardiovasc. sci. (Impr.) ; 32(4): 368-373, July-Aug. 2019. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1012344

ABSTRACT

Cardiopulmonary exercise testing is widely used in the evaluation of patients with left ventricular dysfunction, and some of these patients have an implantable cardioverter-defibrillator (ICD). However, this test presents specific challenges because of the susceptibility to ventricular arrhythmias during maximal levels of exercise. Objective: To evaluate the safety of cardiopulmonary exercise testing in patients with ICD. Methods: The study included patients with ICD who underwent cardiopulmonary exercise testing between 2007 and 2015. The tests were completed once the electronic devices were programmed. The maximum allowed heart rate reached during exercise was 10 beats below the first therapy zone programmed. Results: The study included 69 patients with mean age 53.7 ± 10.8 years, including 68% men. Exercise time was 8.7±2.3 minutes, with peak oxygen consumption of 13.3 ± 4.3 ml.kg-1.min-1. Peak heart rate was 62.9 ± 13.4% of the maximum rate predicted, with all patients taking specific medication. Ventricular arrhythmia was observed in 29% of the patients, and paired ventricular extrasystoles, ventricular bigeminism or non-sustained ventricular tachycardia were observed in only 14.5% of the patients. There was no sustained ventricular arrhythmia resulting in ICD therapy or other complications, such as inappropriate therapies. The frequency of severe events was 0%, 95% CI (0 - 5.2%). Conclusion: In the sample of patients evaluated, the cardiopulmonary exercise testing was shown to be safe during its performance in a hospital setting, following the safety standards


Subject(s)
Humans , Male , Female , Middle Aged , Retrospective Studies , Defibrillators, Implantable , Exercise Test/methods , Oxygen Consumption , Arrhythmias, Cardiac , Cardiovascular Diseases , Body Mass Index , Death, Sudden, Cardiac , Electrocardiography/methods , Data Analysis , Heart Rate
18.
Arq. bras. cardiol ; 112(5): 491-498, May 2019. tab, graf
Article in English | LILACS | ID: biblio-1011193

ABSTRACT

Abstract Background: The use of Cardiovascular Implantable Electronic Devices (CIED), such as the Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy (CRT), is increasing. The number of leads may vary according to the device. Lead placement in the left ventricle increases surgical time and may be associated with greater morbidity after hospital discharge, an event that is often confused with the underlying disease severity. Objective: To evaluate the rate of unscheduled emergency hospitalizations and death after implantable device surgery stratified by the type of device. Methods: Prospective cohort study of 199 patients submitted to cardiac device implantation. The groups were stratified according to the type of device: ICD group (n = 124) and CRT group (n = 75). Probability estimates were analyzed by the Kaplan-Meier method according to the outcome. A value of p < 0.05 was considered significant in the statistical analyses. Results: Most of the sample comprised male patients (71.9%), with a mean age of 61.1 ± 14.2. Left ventricular ejection fraction was similar between the groups (CRT 37.4 ± 18.1 vs. ICD 39.1 ± 17.0, p = 0.532). The rate of unscheduled visits to the emergency unit related to the device was 4.8% in the ICD group and 10.6% in the CRT group (p = 0.20). The probability of device-related survival of the variable "death" was different between the groups (p = 0.008). Conclusions: Patients after CRT implantation show a higher probability of mortality after surgery at a follow-up of less than 1 year. The rate of unscheduled hospital visits, related or not to the implant, does not differ between the groups.


Resumo Fundamento: O uso de dispositivos cardíacos eletrônicos implantáveis (DCEI) como o cardiodesfibrilador (CDI) e terapia de ressincronização cardíaca (TRC) - é cada vez maior. O número de eletrodos de estimulação e desfibrilação varia de acordo com o dispositivo. A colocação do eletrodo no ventrículo esquerdo aumenta o tempo cirúrgico podendo associar-se a maior morbidade no acompanhamento após alta hospitalar, evento muitas vezes confundível com a gravidade da patologia base. Objetivo: Avaliar a taxa de internação não programada na emergência e óbito após cirurgia de dispositivos implantáveis estratificados pelo tipo de aparelho. Métodos: Estudo de coorte prospectivo analisando 199 pacientes submetidos à implante de dispositivos cardíacos. Os grupos foram divididos de acordo com o tipo de dispositivo: CDI (n = 124) e TRC (n = 75). Estimativas de probabilidades foram analisadas pelo método de Kaplan-Meier de acordo com o desfecho. Valor de p < 0,05 foi considerado significativo nas análises estatísticas. Resultados: A maioria da amostra era do sexo masculino (71,9%) - idade média de 61,1 ± 14,2. A fração de ejeção do ventrículo esquerdo foi similar entre os grupos (TRC 37,4 ± 18,1 vs. CDI 39,1 ± 17,0; p = 0,532). A taxa de visita não programada na emergência relacionada ao dispositivo foi de 4,8% no grupo CDI e de 10,6% no grupo TRC (p = 0,20). A probabilidade de sobrevida relacionada ao dispositivo da variável "óbito" mostrou-se diferente entre os grupos (p = 0,008). Conclusões: Paciente após o implante de TRC apresenta maior probabilidade de mortalidade após o procedimento cirúrgico no seguimento menor que 1 ano. A taxa de visita hospitalar não programada, relacionadas ou não ao implante, não difere entre os grupos.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable/statistics & numerical data , Cardiac Resynchronization Therapy Devices/statistics & numerical data , Patient Readmission/statistics & numerical data , Time Factors , Prospective Studies , Follow-Up Studies , Defibrillators, Implantable/adverse effects , Emergency Service, Hospital/statistics & numerical data , Kaplan-Meier Estimate , Cardiac Resynchronization Therapy Devices/adverse effects
20.
Arq. bras. cardiol ; 112(1): 91-103, Jan. 2019. tab, graf
Article in English | LILACS | ID: biblio-973829

ABSTRACT

Abstract Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) was initially recognized as a clinical entity by Fontaine and Marcus, who evaluated a group of patients with ventricular tachyarrhythmia from a structurally impaired right ventricle (RV). Since then, there have been significant advances in the understanding of the pathophysiology, manifestation and clinical progression, and prognosis of the pathology. The identification of genetic mutations impairing cardiac desmosomes led to the inclusion of this entity in the classification of cardiomyopathies. Classically, ARVC/D is an inherited disease characterized by ventricular arrhythmias, right and / or left ventricular dysfunction; and fibro-fatty substitution of cardiomyocytes; its identification can often be challenging, due to heterogeneous clinical presentation, highly variable intra- and inter-family expressiveness, and incomplete penetrance. In the absence of a gold standard that allows the diagnosis of ARVC/D, several diagnostic categories were combined and recently reviewed for a higher diagnostic sensitivity, without compromising the specificity. The finding that electrical abnormalities, particularly ventricular arrhythmias, usually precede structural abnormalities is extremely important for risk stratification in positive genetic members. Among the complementary exams, cardiac magnetic resonance imaging (CMR) allows the early diagnosis of left ventricular impairment, even before morpho-functional abnormalities. Risk stratification remains a major clinical challenge, and antiarrhythmic drugs, catheter ablation and implantable cardioverter defibrillator are the currently available therapeutic tools. The disqualification of the sport prevents cases of sudden death because the effort can trigger not only the electrical instability, but also the onset and progression of the disease.


Resumo A cardiomiopatia/displasia arritmogênica do ventrículo direito (C/DAVD) foi inicialmente reconhecida como uma entidade clínica por Fontaine e Marcus que avaliaram um grupo de pacientes com taquiarritmia ventricular proveniente de um ventrículo direito (VD) estruturalmente comprometido. Desde então, houve avanços significativos na compreensão da fisiopatologia, manifestação e evolução clínica e prognóstico da patologia. A identificação de mutações genéticas comprometendo os desmossomos cardíacos levou a inclusão desta entidade na classificação das cardiomiopatias. Classicamente, a C/DAVD é uma doença hereditária que se caracteriza por arritmias ventriculares, disfunção ventricular direita e/ou esquerda; e substituição fibro-gordurosa dos cardiomiócitos; cuja identificação pode ser muitas vezes desafiadora, devido à apresentação clínica heterogênea, expressividade intra- e inter-familiar altamente variável e penetrância incompleta. Na falta de um padrão-ouro que permita o diagnóstico da C/DAVD, várias categorias diagnósticas foram combinadas e, recentemente revisadas buscando uma maior sensibilidade diagnóstica, sem comprometer a especificidade. A descoberta de que as anormalidades elétricas, particularmente as arritmias ventriculares, geralmente precedem anormalidades estruturais é extremamente importante para a estratificação de risco em membros genéticos positivos. Entre os exames complementares, a ressonância magnética cardíaca (RMC) possibilita o diagnóstico precoce de comprometimento ventricular esquerdo, mesmo antes das anormalidades morfofuncionais. A estratificação de risco continua a ser um grande desafio clínico e medicamentos antiarrítmicos, ablação de cateter e desfibrilador cardioversor implantável são as ferramentas terapêuticas atualmente disponíveis. A desqualificação do esporte previne casos de morte súbita uma vez que o esforço pode desencadear não só a instabilidade elétrica, mas também deflagrar o início e a progressão da doença.


Subject(s)
Humans , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/therapy , Magnetic Resonance Imaging/methods , Risk Factors , Defibrillators, Implantable , Risk Assessment , Body Surface Potential Mapping/methods , Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Electrocardiography
SELECTION OF CITATIONS
SEARCH DETAIL